On/Off or Value

Option

Default

Description

Dynamic

v

a2prio

Use this option to set the alarm priority cutoff used in Alarm Queue Colors (program #1649).

SBN applies the Standard Color to an incident in the Alarm Queue as defined in program #1649 if the incident priority is a lower number than the value of this option.

SBN applies the Priority Color to an incident in the Alarm Queue as defined in program #1649 if the incident priority is a higher number than the value of this option.

+

v

a2qcol0 - a2qcol15

These options are now retired. They have been replaced by Alarm Queue Colors (program #1649).

Taking actions on alarms with priorities greater than the priority defined in option a2prio causes those alarms to appear in the Alarm Queue with the colors defined in options a2qcol0 - a2qcol15. When you define a value for option a2prio, you can designate two colors for each alarm status: one for an alarm priority lower than the priority set in a2prio and one for an alarm priority greater than the priority set in a2prio. These options expand on color options alqcol0 - alqcol15 already in place to indicate alarm status in the Alarm Queue.

+

v

ad_fqdn

kermit_ibsoft.local

Use this option to pull cn from AD

+

v

ad_login

1

This option is used as a common login when authentication is via an active directory.

+

v

ad_path

CN=Users,DC=IBS.DC=corp

This option is used to read AD data.

+

v

addrcom

Itrim[ad.street1no1+’’]+ad.street1+’’

+ad.street1no2

Use this option to define the address column of Alarm Queue.

v

addrcom

namecom

citycom

phoform

phoform2

faxform

These six options define the fields, number of characters and display format in all windows that use the combined name feature in read-only mode.

Fields & # of characters on the address line.

Fields & # of characters on the name line.

Order of fields on the city line.

Format to use for phone number.

Format to use for second phone number.

Format to use for fax number.

v

adj_prc

ADJ

Use this option to define the default price list group to use on adjustments in Contract Master.

Changes made in the adjustment window create a closed work order in the background; used in program #1771.

v

adjwotp

ADJ

Use this option to define the default work order type to use for adjustments on accounts.

Changes made in the adjustment window create a closed work order in the background; used in program #1796.

SBN displays the default work order type in the language associated with the dealer for the installation.

+

c

adspl

On

When this option is on, Address splits into First Name / Last Name.

After IBS initially sets this option, it cannot change the setting.

v

af

2

Use this option to define the number of decimal points in currency.

v

af1

0

Use this option to define the number of trailing characters to ignore in two-decimal amounts.

v

af2

100

Use this option to define the currency factor (10 to the power &af&).

v

alaabc

ZONES_R_____OC

Use this option to identify a status that can be set manually..

  1. R - Restore
  2. O - Open
  3. C - Close

v

alaabr

ARBcSYTMUL P Q

Use this option to define the one letter Alarm abbreviation to use in Monitoring.

  1. A - Alarm
  2. R - Restore
  3. B - Battery
  4. c - Cancel
  5. S - Supervisor
  6. Y - Bypass
  7. T - Trouble
  8. M - Missing (open/close)
  9. U - Unscheduled/Unexpected (open/close)
  10. L - Late (open/close)
  11. P - Previously reported events. (Position 13 was the indicator in prior releases.)
  12. Q - Previously reported events. (Position 21 is the indicator for current releases.)

+

v

alaabs

Use this option to identify physical status indicator in Monitoring..

  1. A - Alarm
  2. R - Restore
  3. B - Battery
  4. c - Cancel
  5. S - Supervisor
  6. Y - Bypass
  7. T - Trouble
  8. P - Previously reported events. (Position 13 was the indicator in prior releases.)
  9. O - Open
  10. C - Close
  11. L - Late
  12. io - In/Out of Service. Special HSL Commands for HWUSA.

+

v

alareo

RNA

Use this option to identify restored status for restored zones.

  1. R - Restore
  2. N - Not Restored

+

v

alares

RNOCP

Use this option to identify a status that can be considered restored.

  1. R - Restore
  2. N - Not Restored
  3. P - Previously reported events. (Position 13 was the indicator in prior releases.)
  4. O - Open
  5. C - Close.

+

v

alatyp

XXXXXXXXXXX

Use this option to generate signal types for positions 1-20.

  1. Position 1: Alarm
  2. Position 2: Restore
  3. Position 3: Battery
  4. Position 4: Cancel
  5. Position 5: Supervisor
  6. Position 6: Bypass
  7. Positions 7-20 Used by various other signal types and should not be changed from the default.

For example, an X in the first position tells SBN to generate an alarm when it receives an alarm signal type. A space in the first position tells SBN not to generate an alarm when it receives an alarm signal type. By setting option alatyp to "X_X_X_XXXXXXXXXXXXXX", SBN generates Alarms for Alarm, Battery, and Supervisor signals, but does not generate alarms for Restore, Cancel, or Bypass signals.

v

albgcol

1

Default Alarm Log Background Color


v

algtyp

XXXXXXXXXXX

Use this option to generate larms or create a log for positions 1-20, but only if that signal is in the Master Queue for the CID..

  1. Position 1: Alarm
  2. Position 2: Restore
  3. Position 3: Battery
  4. Position 4: Cancel
  5. Position 5: Supervisor
  6. Position 6: Bypass
  7. Positions 7-20 Used by various other signal types and should not be changed from the default.

An X in the specific position tells SBN to generate an alarm for that signal type when an alarm of this type, for this CID, appears in the Master Queue. A space tells SBN to only log the event if this type of signal, for this CID, currently appears in the Master Queue.

For example, by setting option alatyp to <<XXXXX_XXXXXXXXXXXXXX>> and option algtyp to << X_X_XXXXXXXXXXXXXXXX>>, SBN generates exceptions for Alarm, Restore, Battery, Cancel, and Supervisor. If the queue has a signal, SBN generates another alarm for Alarm, Battery, and Supervisor. The system does not generate another alarm for Restore or Cancel, but rather only creates a log.

SBN looks to option alatyp first. This means if bysetting option alatyp to not generate an alarm for a specific type, SBN never checks option algtyp for this signal type.

v

allact

ALL

Use this option to define the name to use in Action Profiles (program #1502) to provide access to ALL actions.

v

alqcol0 - alqcol15

These options are now retired. They have been replaced by Alarm Queue Colors (program #1649).

Use these sixteen options to define the color of text in the Alarm Queue when an alarm timer expires and the current event on the alarm is TIO.

Define this option with a legal Windows color name (e.g., Red, Black, Maroon).

  1. If you leave this option blank or use an illegal color name, SBN will use the default colors.
  2. If you define the text color the same as the background color, SBN will change the background color in the Alarm Queue so that you may see all lines of text.
  3. The Alarm Timer background job must be running to view these additional colors.
  4. IBS strongly recommends that you do not experiment or change the color of text in the Alarm Queue unless absolutely necessary.

+

v

amo1099

0

Use this option to define the minimum dollar amount of annual purchases for a vendor that SBN includes in Government form #1099 - Vendor Export (Accounts Payable Export 85).

v

ansinull

ansinull

"set ansinull on/off" on Sybase, "set ansi_nulls on/off" on MSSQL


c

api3off

On

used to control logging in option triggers

-

v

api_eng


URL to APIEngine


v

apichn

When this option is on, it sets the Any mode on API procedures.

v

apitchk

When this option is on, it conducts a tight parameter check on APIs.

c

aqalid

On

When this option is on, CID number appears in the Alarm Queue and the Test Queue.

When this option is off, the installation number appears in both.

v

aqbgcol

1

Default Alarm Queue Background Color


v

aqname

NAME

Use this option to define what data users see in the Name field in the Alarm Queue.

c

asap

Off

This option must be on in order to use the ASAP Address Verification Queue (program #1675) and eDispatch to send alarm incidents to a PSAP in Dispatch (program #537).

Everything else that must be configured before ASAP works is on the ASAP Setup page.

To apply this static option, the following SQL files must be recompiled:

./css/SQL_Sources/Basics/tri_addresses.sql

./css/SQL_Sources/Co_Monitoring/pro_ma_actplan_call_lin_upd.sql

./css/SQL_Sources/Co_Monitoring/pro_ma_installations_upd.sql

./css/SQL_Sources/Service/pro_ma_sv_get_alog.sql

./css/ss/ba/tri_addresses.sql

./css/ss/ma/pro_ma_actplan_call_lin_upd.sql

./css/ss/ma/pro_ma_installations_upd.sql

./css/ss/sv/pro_ma_sv_get_alog.sql

./css/SQL_Sources/Co_Monitoring/pro_ma_asap_addresses.sql

./css/SQL_Sources/Co_Monitoring/pro_ma_asap_chat.sql

./css/SQL_Sources/Co_Monitoring/pro_ma_asap_queue.sql

./css/ss/ma/pro_ma_asap_addresses.sql

./css/ss/ma/pro_ma_asap_chat.sql

./css/ss/ma/pro_ma_asap_queue.sql

v

asapadri

Use this option to define the event extension that SBN records in the Alarm Log when SBN has sent an installation address to an agency to be verified (in program #1675) and the agency determines that the address is invalid.

+

v

asapadrs

Use this option to define the event extension that SBN records in the Alarm Log when SBN submits an installation address to an agency to be verified in program #1675.

+

v

asapadrv

Use this option to define the event extension that SBN records in the Alarm Log when SBN has sent an installation address to an agency to be verified (in program #1675) and the agency determines that the address is valid.

+

v

asapalma

Use this option to define the event extension that SBN records in the Alarm Log to indicate that the PSAP accepted the incident when you send an alarm incident to a PSAP to be handled outside of SBN.

+

v

asapalmr

Use this option to define the event extension that SBN records in the Alarm Log to indicate that the PSAP rejected the incident when you send an alarm incident to a PSAP to be handled outside of SBN.

+

v

asapalms

Use this option to define the event extension that SBN records in the Alarm Log when you submit an alarm incident to a PSAP to be handled outside of SBN.

+

v

asaparrv

Use this option to define the event extension that SBN records in the Alarm Log to indicate that the agency arrived at the installation when you send an alarm incident to a PSAP to be handled outside of SBN.

+

v

asapclos

Use this option to define the event extension that SBN records in the Alarm Log to indicate that the agency closed the alarm incident when you send an incident to a PSAP to be handled outside of SBN.

+

v

asapdisp

Use this option to define the event extension that SBN records in the Alarm Log to indicate that the agency has been dispatched to the installation when you send an alarm incident to a PSAP to be handled outside of SBN.

+

v

asapevt

Use this option to define the monitoring event that SBN records in the Alarm Log when you send an alarm incident to a PSAP to be handled outside of SBN. This is the same monitoring event that SBN records in the Alarm Log when a PSAP sends alarm incident updates to SBN, and when installation addresses are sent to agencies to be verified in program #1675.

+

v

asapmsgi

Use this option to define the event extension that SBN records in the Alarm Log to indicate that SBN received an eDispatch Chat message from an agency.

+

v

asapmsgo

Use this option to define the event extension that SBN records in the Alarm Log to indicate that a monitoring operator sent an eDispatch Chat message to an agency.

+

v

asapmsgr

Use this option to define the event extension that SBN records in the Alarm Log to indicate that an agency rejected an eDispatch Chat message that a monitoring operator sent to the agency.

+

v

asaptmot

Use this option to define the event extension that SBN records in the Alarm Log to indicate that an agency did not respond to an eDispatch alarm incident that an SBN operator sent to the agency and the request has timed out.

+

c

asapupd

Off

This option controls ASAP GEO address updates, which let an agency return a corrected latitude and longitude for an installation address it has verified.

To apply this static option, the following SQL files must be recompiled:

./css/SQL_Sources/Co_Monitoring/pro_ma_asap_upd_geo.sql

./css/ss/ma/pro_ma_asap_upd_geo.sql

v

atf_man


ATF Installed Comp tab url


v

atf_trig


ATF Dispatch tab url


v

atomuse2

public

Use this option to define a user for ATOM procedures.

v

atomuse3

public

Use this option to define a user for ATOM procedures.

v

atomuser

Public

Use this option to define a user for ATOM procedures who can grant permissions for security purposes with ATOM APIs.

v

attpath

blank

Use this option to define the file path where document files are stored.

You may send the file names to SBN using an external software application. SBN creates an entry in the Communication Log (program #1888) with a hyperlink to a document file if the file name matches an Input File Mask entered in Attachment Rules (program #1646).

This option is dealer-based.

+

c

autofeed

Off

When this option is on, SBN automatically gets the next alarm in the queue in Dispatch 10 seconds after a user resolves the current alarm.

  1. This feature is also controlled by Action 537/125, which enables the user to see the check mark for the auto-feed in the Dispatch tab.

v

axiscl1


URL used to obtain session id


v

axiscl2


Username to obtain session id


v

axiscl3


Password to obtain session id


v

axiscl4


URL for video portal